Installation/Press-Loc Spill-Out
 
 

A. Snap-on decorative aluminum fascia, 30” long, factory notch with welded end caps to cover exposed secure bar and scupper pan. Joint treatment with joining fascias consists of a 3/8” expansion reveal and a 4” wide concealed splice plate.
B. Extruded aluminum secure bar, 30” long, factory notched to accomodate scupper pan.
C. (3 Holes) Fasten to wood plates with
#12 x 1-1/2” wood screws.
D. Stainless steel tension clips placed at each side of notched opening.
E. Factory welded scupper pan with exposed surfaces finished to match decorative fascias. See primary roof
material manufacturer’s specification and installation details for proper flashing of this component. Thermoplastic roofs will require installer to fabricate scupper pan from metal designed to be used with that type of
roof membrane.
F. Flashing sheet as specified by membrane
manufacturer.
G. Optional metal edging by installer. Metal edging is not optional when spillout scuppers are used. Metal edging
must be cut to fit over scupper pan.
H. Continuous wood plate & roof structure.

 
  ----------------------------------------------------------
Copyright © 2002 Perimeter Systems,
A Division of Southern Aluminum Finishing Company, Inc.